(OEM 11617502275, 11617544805, 11617502269, 11617544806, 116111440049)
Exchange membrane vacuum chamber. | |
Open the cover of the vacuum chamber. Press the latches, lock them, pry the lid vacuum chamber with a screwdriver. | |
In the photo you can see the removed cover the vacuum chamber. | |
Remove the stem from the membrane. | |
Replace the membrane. Gently insert the rod into place and close the vacuum chamber (do not forget the spring). | |
THE END |